Patient Monitor CO2 Sensor External Sidestream EtCO2 Sensor CO2 Module Veterinary Equipment Accessories
Patient Monitor CO2 Sensor External Sidestream EtCO2 Sensor CO2 Module Veterinary Equipment Accessories
Patient Monitor CO2 Sensor External Sidestream EtCO2 Sensor CO2 Module Veterinary Equipment Accessories
44191792431304

Patient Monitor CO2 Sensor External Sidestream EtCO2 Sensor CO2 Module Veterinary Equipment Accessories

Regular price$1,098.00
/
Color
Ships From
  • FREE SHIPPING THROUGHOUT THE CONTINENTAL U.S.
  • In stock, ready to ship
  • Backordered, shipping soon

SPECIFICATIONS

Brand Name: YUKUI

Origin: Mainland China

Target Pet: Dog & Cat

Screen Size: 12.1 inch

Suitable for: animal

Target Pet: Dog & Cat

Set Type: Yes

Item Type: Veterinary Monitor

Sample Rate: 50 mL/min, ±10mL/min

Power Consumption: Less than 1.5 Watts typical

Transducer Type: Sidestream CO2 sensor

Voltage Requirements: 5.0 VDC ±5%

Technical Specifications

Transducer Type: Sidestream CO2 sensor

Sample Rate: 50 mL/min, ±10mL/min.

Principle of Operation: Non-dispersive infrared (NDIR) single beam optics, dual wavelength, no moving parts

Initialization Time:

Ø Capnogram displayed in less than 5 seconds

Ø Reaching full specifications within 10 minutes.

CO2 Measure Range:

Ø 0 - 114 mmHg

Ø 0 - 15%

Ø 0 - 15.2kPa

CO2 Resolution:

Ø 0.1 mm Hg 0 to 50 mm Hg

Ø 0.25 mm Hg 50 to 114 mm Hg

CO2 Accuracy:

Ø 0 – 40 mmHg ±2 mmHg

Ø 40 – 114 mmHg ±5% of reading

Respiratory Rate:

Ø Range 2 to 120 Breaths Per Minute (BPM)

Ø Accuracy ±1 breath

Calibration:

No routine user calibration required

Compensation:

Automatic Barometer Pressure 400 - 800 mmHg.

User selectable O2 / N2O compensation.

Voltage Requirements: 5.0 VDC ±5%

Power Consumption: Less than 1.5 Watts typical.

Temperature and Humidity:

Operating: 0º to 40ºC, 10 to 90% RH, non-condensing

Storage: -40º to 70ºC, <90% RH, non-condensing

Interconnection:

Pin out:

1. VA 5.0V

2. Shield Shield

3. DGND Digital return

4. VSRC Unused

5. TxD Serial data from LH800

6. RxD Serial data from Host

7. AGND Analog return

8. SYNC Unused

Data Interface:

Ø RS232, bi-directional, 19200 baud rate, standard N-8-1.

Ø Fully compatible with Respironics LoFlo communication protocol

Data Output:

CO2 gas concentration (mm Hg), End-tidal CO2, Inspired CO2, Respiratory Rate, Automatic barometric pressure compensation.
NOTE: No host



NOTE: No host

We never leave quality to chance. We pay detailed attention to our production, and our shipments are hand packed and carefully inspected before leaving our warehouse. But in the event your order was not fulfilled correctly or you are not satisfied with your purchase, please contact us immediately by aliexpress or email. We will fully replace any items you are not happy with or send you a refund. You can give the best suited use to any unwanted items. Our commitment to quality is reflected in several initiatives that allow moon-Papillon to constantly monitor and improve our services, processes and products, thus assuring 100% satisfaction.